- Home
-
Shop
- Assistive Devices
- Cerumen Management
- Clinical Tools & Supplies
-
Diagnostic Equipment & Supplies
Diagnostic Equipment & Supplies
- ABR & OAE Systems
- Air, Bone & Insert Earphones
- Audiograms & Forms
- Audiometers
- Auditory Test Recordings
- Balance Supplies
- Electrodes & Supplies
- Hearing Instrument Programming & Test Box
- Infant Screening Supplies
- Recording Paper
- REM Systems & Probe Tubes
- Tympanometers, Printers & Parts
- Tuning Forks
- Misc Parts & Supplies
- VRA & E-CPA
- Eartips
- Fitting Supplies
- Hearing Conservation
- Impression Materials
- Infection Control
- Mobile Audiology
- Office & Educational Items
- Otoscopes & Headlamps
- Resale Accessories
- Home>
- Catalog>
- Diagnostic Equipment & Supplies>
- Audiometers>
- Diagnostic Audiometers>
- Resonance R37A High Frequency Clinical Audiometer
Resonance R37A High Frequency Clinical Audiometer
Product Code: R37A-HF
- Two-channel, high frequency (20 kHz) diagnostic audiometer with air, bone, speech and additional special test capabilities
- Air conduction
- frequency range: 125 Hz to 20000 Hz
- attenuation levels: -10 dBHL to 120 dBHL (step size 5 dB, 2 dB, 1 dB)
- packaged with calibrated HD300 audiometric headphones
- includes patient response button
- built-in talk forward microphone
- talk-balk function
- manual testing capabilities only
- Bone conduction
- frequency range: 250 Hz to 6000 Hz
- attenuation levels: -10 dBHL to 80 dBHL
- packaged with calibrated B71 BC vibrator
- manual testing capabilities only
- Speech audiometry
- Monitored-live voice capabilities
- Recorded speech material capable via external CD player (not included)
- Special test features
- ABLB/MLB Test
- Stenger Test
- GAP Test
- DLF Test
- SISI Test
- Bekesy
- Tone Decay
- Air conduction
- Powered by mains AC/DC adapter (included) that plugs into standard wall outlet
- MDS software (requires license key) allows data transfer to PC through Bluetooth 2.1, data storage (locally or in Noah), reporting and printing features; see Instructions section for MDS licensure activation key document and information
- Three year warranty
- Model with standard 125 Hz to 8000 Hz testing capabilities: item# r27a-DD45
Scroll down and read information in the Before You Buy section
- r27a two-channel diagnostic audiometer
- HD300 headphones
- B71 bone vibrator
- Power supply
- USB drive containing
- certificates and technical documents
- installer file for MDS Resonance Database Management Software
- user manual
- tutorial and procedures
- Medical power supply with 4 plug adapters (including standard AC plug adapter for U.S.)
- Operator headset with microphone
- Patient talk-back microphone
- Patient response switch
- Dust cover
Is there a guide outlining front panel controls and/or how things plug into the back of the unit?
Click Controls & Components tab in the product description; the information is also outlined on pages 34-35 of the user manual (see Product Docs tab, and click User Manual icon).
How do I turn the device on?
Make sure all the necessary transducers required for testing are connected. Connect the power supply cable to the back of the device and plug into wall socket. To turn the device on, press the switch located in the back of the unit (label 33 on the back panel as illustrated in Controls & Components section).
How do I use the built-in printer?
The built-in printer is an obsolete feature and will not function. The MDS software allows data transfer from the audiometer to a PC for data management and report generation. The information transferred to the PC can be printed off from the PC. Another option involves purchasing a compatible external printer that directly connects to the audiometer.
I am getting a License Key activation prompt. What is this and how do I find the License Key for my unit?
When trying to add patient data, the unit accommodates up to five patients. When trying to add the sixth patient, the following Licensure Key activation window will appear:
This means the demo version of the MDS software has expired and it will be necessary to enter the License Key associated with your specific unit. The MDS License Key is listed in the PDF file called Resonance License located within the MDS folder on the USB thumb drive that came packaged with the unit. If you are unable to find the PDF file, contact Oaktree Products with the make/model and serial number of your unit. We will make arrangements for the vendor to issue the necessary MDS License Key.
How to I store values on the audiogram?
Press the STORE (17) button as illustrated in Controls & Components sections. NOTE: values cannot be stored if the R+L function is activated (i.e. if signal transmission is provided simultaneously to both ears).
How do I talk to the patient (talk forward)?
The operator can communicate with the patient either via a built-in microphone (3) or operator headset with microphone (included; connects to back panel). Once the operator headset with microphone is connected via the rear panel, the built-in microphone will be deactivated. To talk to the patient, press the T. Over button (15) and keep it pressed while speaking. The patient will be able to hear the operator via the transducers used for test performance (headphones, bone conductor, speakers). Volume levels of the operator talk forward microphone and the operator headset can be adjusted by selecting the CONTROLS (14) key and using arrow keys or Ch1 and Ch2 dials. See Controls & Components for visual orientation to buttons and controls of this unit.
How does talk back work (e.g. hearing what the patient is saying)?
The patient speaks to the operator over the patient microphone that is connected to the unit via the rear panel (25). The operator can hear the patients via the built-in monitor speaker of the audiometer or via the operator headset, which is connected to the appropriate connector located on the unit’s rear panel (27). Once the operator headset is connected via the rear panel, the built-in speaker is excluded. The patient microphone can be adjusted by selecting the CONTROLS (14) key and using arrow keys or CH 1 and CH2 dials. See Controls & Components for visual orientation to buttons and controls of this unit.
CONTROLS AND COMPONENTS (FRONT SECTION)
1. Display
2. Built-in thermal printer compartment (obsolete; this audiometer requires external printer)
3. microphone (talk forward)
4. Channel 1 & 2 dials
5. F1 - F6 function keys
6. Test key: when in testing mode, this key returns to main menu
7. Enter key: when in test mode, key for accessing tests from main menu
8. Right vs left ear inputs
9. Output/input for each channel
10. Arrow keys: to navigate menus
11. Norm/Rev: for signal transmission. Norm mode (output signal present when pressing SIGNAL button); rev mode (output signal constant and stopped when pressing SIGNAL button)
12. Signal: when audiometer in Norm mode, press button to present signal; in rev mode, press button to stop signal
13. Frequency
14. Controls: provides access to external signal adjustment and calibration page, for monitor-headset, for patient-to-operator mic (talk back), and for operator-to-patient mic (talk forward)
15. T over: talk forward microphone volume
16. Star/Stop: enables start/stop of special features/tests (auto threshold, SISI, Tone Decay, Bekesy)
17. Store: storage/display of threshold values
18. Print: prints test results to printer or to generate PDF report
CONTROLS AND COMPONENTS (BACK SECTION)
19. right (red) and left (blue) standard headphones (DD45)
20. high frequency headphones (DD450)
21. sound masking
22. B71 bone vibrator
23. free field
24. external cd player
25. talk back microphone
26. talk forward operator microphone
27. operator monitor headset
28. patient response button
29. second patient response button (note: obsolete)
30. SD card (speech test materials packaged with device)
31. port for optional USB keyboard and external USB data
32. PC communication and data transfer
33. ON-OFF switch with main fuse holders and main power supply connection
34. optional operator microphone port
Things to Know Before you Buy
The built-in printer feature is obsolete and no longer functional
At the end of 2021, the printer was discontinued and Resonance was unable to find a comparable replacement that would fit in the unit. Rather than redesigning the r27a form factor, the built-in printer comportment remains on current units.
The unit does come packaged with free MDS software that allows data transfer from the audiometer to your PC for data management and report generation. The transferred data can be printed off from your PC. This represents the most common way providers print data from this unit. Another option for printing data from the unit is to purchase a compatible external printer that connects directly to the unit.
Technical support, calibration, and service is provided and managed through Oaktree Products
Responsive, efficient, and effective support is critical for busy providers to be able to use their equipment without delay. Equipment calibration is required annually. Equipment may need to be serviced over the years. Oaktree Products has made arrangements to coordinate and provide support, calibration and service to allow providers to focus on their clinical practice.
NOTE:
- see PRODUCT DOCUMENTS tab and click SOFTWARE MANUAL to download MDS User Manual
- QUICK START and QUICK START NOAH instructions outlined below after INSTALLATION
Minimal Requirements for PC to work with MDS Software:
- Windows XP
- Windows Vista
- Windows 7
- Windows 8
Minimal Requirements for Noah to work with MDS Software:
- Noah version 4.X.
Resonance MDS Software & License Key:
The Resonance MDS Software is included free of charge with this Resonance unit. The software allows creation and management of a patient database on your PC and the ability to transfer patient information and test results from your Resonance unit to your PC. As a software program, a license key will be required to permanently activate the MDS software. The license key can be found within the Resonance License PDF file that resides in the MDS Suite folder on the USB thumb drive packaged with your unit. Print or refer to this file when your unit generates a prompt for MDS License Key Activation.
MDS License Key Activation:
The MDS software file resides in the MDS folder on the USB thumb drive packaged with your unit. The software is located on the USB thumb drive packaged with the unit. Go to the MDS Suite folder, click MDS Setup and follow installation instructions. Be sure to click "Create Shortcut to Desktop" when prompted to have the software icon appear on your desktop for easiest access. NOTE: MDS software will accommodate data from five patients without requiring a software license activation key. When trying to add data from the sixth patient, the following Licensure Key activation window will appear:
This means the demo version of the MDS software has expired and it will be necessary to enter the License Key associated with your specific unit. The MDS License Key is listed in the PDF file called Resonance License located within the MDS folder on the USB thumb drive that came packaged with the unit. If you are unable to find the PDF file, contact Oaktree Products with the make/model and serial number of your unit. We will make arrangements for the vendor to issue the necessary MDS License Key.
Cables for Connection with PC:
The Resonance device can be connected to a PC using a USB cable (included)
INSTALLATION:
- Insert USB drive to PC
- Double click file "MRS Resonance Setup.exe" to begin install
- select YES if prompted with "Do you want to allow the following program from an unknown publisher make changes to your computer?"
- Select language for installation from provided choices
- At the Welcome screen, to continue, select NEXT
- When prompted "Would you like to install this device software?", check the box next to "Always trust software from MRS Srl", then click INSTALL
- When installation complete, select either "Run MRS Resonance Now" to run the program immediately, or click FINISH to complete installation and exit the program
- The icon of the program will now be present on the PC desktop and in the program bar called MRS Resonance
Quick Start Instructions:
- launch program
- at the authentication window, "admin" will populate as UserName
- type "a" (lower case letter a) as the password (password can be changed later)
- check the box "remember me" to no longer have the authentication window populate when launching program
- click SESSIONS (upper horizontal menu bar)
To Create a New Patient:
- click NEW (from upper horizontal menu bar)
- fill the the following MANDATORY FIELDS
- First Name
- Surname
- Birth Date
- Birth Place
- Choose Gender
- click PRIVACY ACCEPTED
- click SAVE to create patient
- click EDIT (to proceed with transferring data from Resonance device to your PC)
Transferring data from Resonance unit to PC:
- after creating NEW patient, the icon "Acquire data from device" will be active
- conduct test on the Resonance unit
- connect Resonance device to the PC where MDS is running
- click on "Acquire data from device"
- an "Acquisition" or "Acquisizione" window will appear
- select the Resonance device from pull down menu appearing under destination patient name
- click DOWNLOAD
- once the system indicates "Acquired Data", click SAVE & EXIT button to store data in database
View transferred test data:
Once data is transferred from a Resonance unit to a PC and saved, the test data will not reside in the '"Patient Historic Sessions" area located in lower left hand portion of the screen. To view the transferred data:
- select SESSIONS tab located in the lower right hand portion of the screen under the image of the patient silhouette
- in the TESTS IN SELECTION SESSION, click VIEW TEST DETAIL
QUICK START NOAH:
- launch MDS
- click icon in the left upper corner of main window
- select TOOLS > Noah > Register Module (this procedure executed one time only)
- close Resonance software suite and run Noah
- once Noah opened, a RESONANCE button will appear in the upper horizontal menu
- to transfer data, follow instructions outlined above QUICK START INSTRUCTIONS, and select a patient in the Noah database
- click RESONANCE button to run MDS
- MDS will initiate; when the "Acquisition" or "Acquisizione" window appears, click DOWNLOAD to transfer data to Noah database